627
Changing to CS1W/CJ1W-NC271/471/F71 from CS1W/CJ1W-NC113/133/213/233/413/433
Appendix E
W-series Servo Drives
CS1W/CJ1W-NC113/133/213/233/413/433
CS1W/CJ1W-NC271/471/F71
Word
Name
Bit
Setting
Setting location
Difference
0004
I/O set-
tings
00
Output pulse selec-
tion
---
---
Output pulse selection is not pro-
vided, so this parameter setting is not
available.
01 to
03
Not used.
---
---
---
04
Limit input signal
type
Servo Parame-
ter Area
Pn50A.3
Pn50B.0
Sets the input signal logic using the
input allocations for the for-
ward/reverse drive prohibited signals.
05
Origin proximity input
signal type
Servo Parame-
ter Area
Pn511.0
Sets the input signal logic using the
input allocations for the origin return
deceleration LS signals.
06
Origin input signal
type
Servo Parame-
ter Area
Pn511.1
Pn511.2
Pn511.3
Sets the input signal logic according
to the input allocations for the exter-
nal latch signal when external latch
signal is selected as the origin input
signal. This setting is not available
when the Servomotor phase Z signal
is selected as the origin input signal.
07
Emergency stop
input signal
---
---
An emergency stop input signal is not
provided, so this parameter is not
available.
The stop methods used for limit
inputs and software limits, however,
can be specified in Servo Parameter
Pn001.1. (For details, refer to
7-5
Limit Input Operations
.)
08
Origin undefined
designation
---
---
This parameter setting is not avail-
able.
The Servo Drive's feedback position
is obtained. Therefore, the origin is
not lost even when operation stops
due to an external sensor.
09 to
15
Not used.
---
---
---
0005
Opera-
tion
mode
selection
00 to
03
Operation mode
Axis Parameter
Area
word d+1
Bits
00 to 03
Not used.
Operation mode selection is not pro-
vided, so this parameter setting is not
available.
04 to
07
Origin search opera-
tion
Bits
04 to 07
This parameter setting is the same.
08 to
11
Origin detection
method
Bits
08 to 11
Not used.
Origin searches always use the origin
proximity input signal.
The origin detection method is fixed
as the method that receives the origin
input signal after the origin proximity
input signal turns from ON to OFF.
(This method corresponds with the
setting when the origin detection
method in the earlier PCUs is set to
0.)
12 to
15
Origin search direc-
tion
Bits
12 to 15
This parameter setting is the same.
Servo Parameter Pn816 (zero point
return direction), however, must be
set at the same time to the same set-
ting as for this parameter. (For
details, refer to
8-2-3 Data Settings
Required for Origin Search
.)
Содержание CJ1W-NC271 - 12-2009
Страница 2: ......
Страница 4: ...iv ...
Страница 6: ...vi ...
Страница 22: ...xxii ...
Страница 58: ...30 Starting Operation Section 2 2 ...
Страница 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Страница 264: ...236 Transferring Servo Parameters Section 5 3 ...
Страница 396: ...368 Linear Interpolation Section 9 7 ...
Страница 648: ...620 List of Error Codes Appendix D ...
Страница 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 684: ...656 Index ...
Страница 686: ...658 Revision History ...