3
System Configuration
Section 1-2
1-2
System Configuration
The PCU receives commands from the CPU Unit's ladder program and con-
trol signal status (forward/reverse rotation limit, origin, origin proximity, and
interrupt input signals) from devices connected externally to the Servo Drive,
and uses them to control Servo Drive positioning.
System Configuration Example
Power Supply Unit
CJ-series
CPU Unit
CJ1W-NCF71
Position Control Unit
Servo Drive
Servomotor
Servo Drive
Servomotor
Servo Drive
MECHATROLINK-II
(16 axes max.)
External inputs
External inputs
Forward rotation limit input signal
Reverse rotation limit input signal
Origin input signal
Origin proximity input signal
Interrupt input signal
Etc.
24-V DC power supply
for interface
Forward rotation limit input signal
Reverse rotation limit input signal
Origin input signal
Origin proximity input signal
Interrupt input signal
24-V DC power supply
for interface
Etc.