333
Absolute Encoder Origin
Section 8-6
To enable setting the absolute encoder zero point position offset with an origin
search operation, the following axis parameter settings must be used with the
above origin search operation pattern.
Origin search preset: Set.
Encoder type: Absolute Encoder
Axis Parameters
The following parameters are used to set the origin search operation mode.
d = 1860 hex + (Axis No.
−
1)
×
14 hex
When setting the absolute encoder's zero point position offset using an origin
search, set the position command value (i.e., the present position preset
value) to 0 and enable the origin search preset even when the preset value is
not being used for the origin search.
Note
• Each time the absolute encoder zero point position offset is set using an
origin search operation, the
Absolute Origin Offset
for G Series (Pn200)
or
Absolute Encoder Zero Point Position Offset
for G5 Series/W Series
(Pn808) is saved to non-volatile memory in the Servo Drive. There is a
limit to the number of times non-volatile memory in the Servo Drive can be
written (10,000 times). Do not save the
Absolute Origin Offset
for G
Series (Pn200) or
Absolute Encoder Zero Point Position Offset
for W
Series (Pn808) too frequently.
• The absolute encoder zero point position offset will not be set correctly
using an origin search operation if an error occurs before origin search
operation is completed. Repeat the operation if an error occurs.
• If the absolute encoder PG zero point position offset is set using an origin
search operation, the MECHATROLINK transfer cycle and communica-
tions cycle settings will need to be changed. Refer to
Transfer Cycle and
Communications Cycle When Setting the Absolute Encoder Zero Point
Position Offset Using an Origin Search Operation with Position Control
Units with Unit Ver. 2.0
on page 246 and set the transfer cycle and com-
munications cycle correctly. If the transfer cycle and communications
cycle are not set correctly, the function to set the absolute encoder PG
zero point position offset using an origin search operation will not operate
correctly.
PCU's
address
Contents
Setting
15 to 14
13
12
11 to 08
07 to 04
03 to 00
d+1
0 (fixed)
Origin
search
preset
Origin
search
direction
Origin
detection
method
Origin
search
operation
0 (fixed)
Set the origin search operation.
Origin search direction
0: Reversal mode 1
Origin detection method
0: With origin proximity input signal
reversal (default setting)
1: Without origin proximity input sig-
nal reversal
2: Not use origin proximity input sig-
nal
Origin search direction
0: Forward (default setting)
1: Reverse
Origin search preset
1: Set
d+2
0 (fixed)
0
0
0 (fixed)
0 (fixed)
Encoder
type
1: Absolute encoder
Содержание CJ1W-NC271 - 12-2009
Страница 2: ......
Страница 4: ...iv ...
Страница 6: ...vi ...
Страница 22: ...xxii ...
Страница 58: ...30 Starting Operation Section 2 2 ...
Страница 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Страница 264: ...236 Transferring Servo Parameters Section 5 3 ...
Страница 396: ...368 Linear Interpolation Section 9 7 ...
Страница 648: ...620 List of Error Codes Appendix D ...
Страница 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 684: ...656 Index ...
Страница 686: ...658 Revision History ...