167
Servo Parameter Area
Section 4-5
Pn526
Deviation
counter
overflow
level at
Servo-ON
4
Sets the deviation counter overflow alarm detection
level for Servo ON.
262144
Com-
mand
unit
1 to
1073741823
Online
---
Pn528
Deviation
counter
overflow
warning
level at
Servo-ON
2
Sets the deviation counter overflow warning detec-
tion level for Servo ON.
100
%
10 to 100
Online
---
Pn529
Speed
limit level
at Servo-
ON
2
Sets the speed limit for when the Servo turns ON
with position deviation accumulated.
10000
r/min
0 to 10000 Online
---
Pn52A
Not used.
---
(Do not change the setting.)
20
---
---
---
---
Pn52F
Not used.
---
(Do not change the setting.)
FFF
---
---
---
---
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting
range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation