Rev.
Date
Editor
Changes
◦ 5014, start addr. 450136, ID 4090
◦
• LogicsManager References update:
•
◦ 07.xx: IDs changed
◦
◦ 09.xx: IDs changed
◦
◦ 10.xx: IDs changed
◦
◦ 11.xx: IDs changed
◦
◦ 13.xx: IDs changed
◦
◦ 15.xx: IDs changed
◦
• Layout optimizations and typo corrections.
•
E
2016-12
GG
NEW Software Revision Release 1.13 or higher
NEW features & functions
• A customer specific device name can be entered and will be used e.g. as device
•
name in Ethernet network. For more details refer to
.
• All monitoring functions in the device are from now on expanded with an
•
additional functionality:
◦ Each monitor can be individually enabled by an internal LogicsManager flag.
◦
(For example refer to parameter »Enabled«
Overfrequency (Level 1 & 2) ANSI# 81O”
• Device identification via settings file: Serial number will be part of the .wset file
•
generated and saved via ToolKit. Device identification, file management, and
support request become much easier.
• AnalogManager became even more flexible:
•
◦ 16 free configurable and accessible constants enable pre-sets to be used as
◦
AnalogManager input. For details refer to
• »Generator Total AC Power« PGN 65029 is send to Scania S6 ECU via J1939
•
protocol. For details refer to
╚═▷ “7.5.3 Device Types "Standard" and "Standard
.
• Power factor values display (generator and mains) enhanced: Three instead two
•
decimal places. Refer to
for details.
• Fuel level monitoring offers two further SPN available via J1939 interface (refer to
•
╚═▷ “Standard visualization messages”
╚═▷ “9.2.7 Protocol 5016 (Basic
◦ SPN 96: 96:Fuel level 1
◦
◦ SPN 38: 09.15 38:Fuel level 2
◦
• The "Protection Lamp DM1" status of the J1939 communication is from now on
•
available as LogicsManager command variable "03.44 Protection lamp DM1". Refer
to
╚═▷ “9.3.2.3 Group 03: Engine control”
• Max number of logged events enhanced: 1000 events saved now instead of 300
•
before. Refer to
• The frequency measurements based on phase-phase and phase-neutral voltages
•
are monitored on plausibility. For details refer to
╚═▷ “4.5.1.3.1 Plausibility Check
• Both alarm class configuration parameters
•
MCB now additionally offer the possibility to select "Control".
• The device stores from now on the three generator current slave pointers in a non-
•
volatile memory.
• The breaker closed transition time in the mode GCB/MCB has been optimized to
•
match the <100 ms duration time. Refer to
for details.
• The Node-ID of the device in a CAN bus network can be automatically pre-set with
•
the device number. Parameter
»Align device no. with Node-ID« must be
configured to "Yes". This will avoid same-number-mismatch.
• Load sharing interface can be switched between CAN and Ethernet. Refer to
•
parameter »Load share interface«
for details.
• Island mode:
•
33
easYgen-3000XT Series
B37574
1 General Information
1.1 Revision History
Released