![Rohde & Schwarz CMW-KE100 User Manual Download Page 436](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807436.webp)
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
436
User Manual 1173.9511.02 ─ 12
Setting
Commands for SA scenario
Commands for CSP scenario
Frequency
CONFigure:EVDO:MEAS<i>:RFSettings:
FREQuency
CONFigure:EVDO:SIGN<i>:RFSettings:
FREQuency?
CONFigure:EVDO:SIGN<i>:RFSettings:
RLFRequency?
or
CONFigure:EVDO:SIGN<i>:RFSettings:CHANnel
Freq. offset
CONFigure:EVDO:MEAS<i>:RFSettings:FOFFset CONFigure:EVDO:SIGN<i>:RFSettings:FOFFset
Expected nom-
inal power
CONFigure:EVDO:MEAS<i>:RFSettings:ENPower CONFigure:EVDO:SIGN<i>:RFPower:EPMode
CONFigure:EVDO:SIGN<i>:RFPower:MANual
CONFigure:EVDO:SIGN<i>:RFPower:EXPected?
Physical layer
subtype
CONFigure:EVDO:MEAS<i>:MEValuation:
PLSubtype
CONFigure:EVDO:SIGN<i>:NETWork:RELease
Carrier config-
uration
CONFigure:EVDO:MEAS<i>:MEValuation:
CARRier:SETTing
CONFigure:EVDO:SIGN<i>:CARRier:SETTing
CONFigure:EVDO:SIGN<i>:PILot:SETTing
CONFigure:EVDO:MEAS<i>:MEValuation:
CARRier:ENABle
CONFigure:EVDO:SIGN<i>:NETWork:PILot:
CSECtor
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AN:
ACTive
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AT:
ASSigned
CONFigure:EVDO:MEAS<i>:MEValuation:
CARRier:FOFFset
not relevant
CONFigure:EVDO:MEAS<i>:MEValuation:
CARRier:FREQuency
CONFigure:EVDO:SIGN<i>:CARRier:CHANnel
CONFigure:EVDO:SIGN<i>:CARRier:
RLFRequency?
3.6 List of Commands
ABORt:EVDO:MEAS<i>:MEValuation...........................................................................................................315
ABORt:EVDO:MEAS<i>:OLTR......................................................................................................................427
CALCulate:EVDO:MEAS<i>:MEValuation:ACP:AVERage?..........................................................................365
CALCulate:EVDO:MEAS<i>:MEValuation:ACP:CURRent?..........................................................................365
CALCulate:EVDO:MEAS<i>:MEValuation:ACP:MAXimum?.........................................................................365
CALCulate:EVDO:MEAS<i>:MEValuation:CP:AVERage?............................................................................360
CALCulate:EVDO:MEAS<i>:MEValuation:CP:CURRent?............................................................................ 360
CALCulate:EVDO:MEAS<i>:MEValuation:CP:MAXimum?........................................................................... 360
CALCulate:EVDO:MEAS<i>:MEValuation:CP:MINimum?............................................................................ 360
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:ACPM<freqpoint>:AVERage?................................... 423
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:ACPM<freqpoint>:CURRent?....................................423
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:ACPM<freqpoint>:MAXimum?...................................423
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:ACPP<freqpoint>:AVERage?....................................423
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:ACPP<freqpoint>:CURRent?.................................... 423
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:ACPP<freqpoint>:MAXimum?................................... 423
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:AVERage?.................................................................396
List of Commands