![Rohde & Schwarz CMW-KE100 User Manual Download Page 162](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807162.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
162
User Manual 1173.9511.02 ─ 12
CONFigure:EVDO:SIGN<i>:CARRier:FLFRequency?
Gets the forward link frequency for a carrier in the cell implemented by the Signaling
Application.
The related carrier has to be pre-selected using the
command.
This frequency is determined by the cell's main carrier channel and the related carrier's
channel offset.
Return values:
<CFwdLinkFreq>
Range:
100E+6 Hz to 6.1E+9 Hz
Example:
See
Usage:
Query only
Firmware/Software:
V2.1.20
Options:
Multi-carrier configurations require option R&S CMW-KS881.
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CARRier:RLFRequency?
Gets the reverse link frequency for a carrier in the cell implemented by the signaling
application.
The related carrier has to be pre-selected using the
command.
This frequency is determined by the cell's main carrier channel and the related carrier's
channel offset.
Return values:
<CRevLinkFreq>
Range:
100E+6 Hz to 6.1E+9 Hz
Example:
See
Usage:
Query only
Firmware/Software:
V2.1.20
Options:
Multi-carrier configurations require option R&S CMW-KS881.
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CARRier:LEVel:ABSolute
<LevelAbsolute>
Sets/gets the absolute 1xEV-DO power level for a carrier.
The related carrier has to be pre-selected using the
command.
While the query can be executed for all carriers, setting the power level is only possible
for carrier 0. The power level of carriers 1 and 2 are specified via their level relative to
carrier 0 - implicitly determining the absolute levels.
Command Reference
深圳德标仪器