![Rohde & Schwarz CMW-KE100 User Manual Download Page 605](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807605.webp)
CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
605
User Manual 1173.9511.02 ─ 12
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:CDMA:SIGN<i>:MSINfo:MEID?
Queries information from the MS. The value shows the Mobile Equipment Identifier of
the MS. It is 56-bit number assigned by the MS manufacturer, uniquely identifying the
MS equipment.
Return values:
<MEID>
14-digit hexadecimal number
Range:
#H0 to #HFFFFFFFFFFFFFF (14 digits)
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:CDMA:SIGN<i>:TEST:MSINfo:MEID
<MEID>
Sets the mobile equipment identifier of the connected MS.
Parameters:
<MEID>
Range:
0 to 9.2233720318
*RST:
0
Example:
See
Firmware/Software:
V3.2.70
Manual operation:
See
CONFigure:CDMA:SIGN<i>:MSINfo:MSUPport?
Queries information from the MS. The value indicates whether the MEID Support bit 4
is set or not.
Return values:
<MEIDSupport>
OFF | ON
*RST:
OFF
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
Command Reference
深圳德标仪器