Parameters:
<MaxIndex>
Range:
1 to 12
*RST:
1
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
"RETAP Configuration > Min / Max Packet Size"
CONFigure:EVDO:SIGN<i>:LAYer:APPLication:RETap:SMAX:SIZE?
Queries the packet size for the selected maximum data rate index (
EVDO:SIGN<i>:LAYer:APPLication:RETap:SMAX:INDex
).
Return values:
<MaxSize>
Range:
0 bits to 12.288E+3 bits
*RST:
128 bits
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
"RETAP Configuration > Min / Max Packet Size"
CONFigure:EVDO:SIGN<i>:LAYer:APPLication:PACKet:PREFerred
<PrefApplication>
Selects the packet application the R&S
CMW initially proposes to the AT during ses-
chapter 2.2.3.2, "Packet Applications"
Parameters:
<PrefApplication>
DPA | EMPA
EMPA:
Enhanced Multi-flow Packet Application
DPA:
Default Packet Application
*RST:
EMPA
Example:
See
Firmware/Software:
V3.0.10
Manual operation:
See
"Packet Configuration > Preferred Application"
2.5.8.3
Release B Application Layer
The following commands configure the forward and reverse test applications (FMCTAP
and RMCTAP) for Release B signals.
This requires option R&S CMW-KS881.