Example:
See
Firmware/Software:
V3.2.20
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:ACP:EXTended:UPPer[:RELative]
<ACPSetting>(20)
Defines upper limits 0 to 19 for the extended ACP measurement in dBc of the selected
carrier (see
CONFigure:EVDO:MEAS<i>:MEValuation:CARRier:SELect
) at the
individual negative offset frequencies (set via
MEValuation:ACP:FOFFsets:LOWer
).
The limit index 0 to 19 corresponds to the index used in manual control.
Parameters:
<ACPSetting>
Range:
-80 dBc to 10 dBc
*RST:
For offset frequencies 0 to 19 all OFF [dBc]:
-43,-43,-43,-54,-54,-54,-54,-54,-54,-54,-54,-54,-54,-
54,-54,-54,-54,-54,-54,-54
Default unit: dBc
Additional parameters: OFF | ON (enables | disables the limit
check)
Example:
See
Firmware/Software:
V3.2.20
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:OBW:MULTi
<OBWLimit>
Gets/sets the overall occupied bandwidth limit and the state of the limit check for multi-
carrier configurations.
Parameters:
<OBWLimit>
Range:
0 MHz to 16 MHz
*RST:
16 MHz
Additional parameter values: OFF | ON (disables | enables the
limit check)
Example:
See
Firmware/Software:
V2.1.20
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:OBW:CHECk
<OBWLimitCheck>
Gets/sets the enabled state of OBW limit checks. Depending on the current band
class, either Limit Set A or B applies.