User Manual 1173.9511.02 ─ 12
The spreading factor used for calculation of the code domain power and code domain
error results is also influenced by the subtype and displayed in the dialog.
In the Standalone (SA) scenario, this parameter is controlled by the measurement. In
the Combined Signal Path (CSP) scenario, it is controlled by the signaling application.
Remote command:
CONFigure:EVDO:MEAS<i>:MEValuation:PLSubtype
(SA)
CONFigure:EVDO:SIGN<i>:NETWork:RELease
(CSP)
CONFigure:EVDO:MEAS<i>:MEValuation:SFACtor?
3.3.5 Multi Evaluation: Carrier Configuration
The parameters in this section configure describe the reverse link carriers to be mea-
sured for multi evaluation measurement.
See also
Multi-Carrier Configurations (Rev. B)
.
Fig. 3-23: Multi evaluation configuration: carrier
......................................................................................... 272
Enable
Up to three carriers can be enabled and measured within the same measurement inter-
val. Carrier 0 is always enabled. Carriers 1 and 2 can be selectively enabled.
In the Standalone (SA) scenario, this parameter is controlled by the measurement. In
the Combined Signal Path (CSP) scenario, it is controlled by the signaling application.
Remote command:
CONFigure:EVDO:MEAS<i>:MEValuation:CARRier:SETTing
(SA)
CONFigure:EVDO:MEAS<i>:MEValuation:CARRier:ENABle
(SA)
CONFigure:EVDO:SIGN<i>:PILot:SETTing
(CSP)
CONFigure:EVDO:SIGN<i>:NETWork:PILot:CSECtor
(CSP)
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AN:ACTive
(CSP)
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AT:ASSigned
(CSP)
Offset to RF / Carrier Freq.
"Carrier Freq." is the center frequency of the related carrier. Setting its value directly is
only possible for carrier 0: the frequencies of carriers 1 and 2 are specified in terms of
their offset to carrier 0. The maximum distance between carriers is restricted to 8 MHz.
GUI Reference