See
CONFigure:EVDO:SIGN<i>:FADing:FSIMulator:RESTart:MODE
<RestartMode>
Sets the restart mode of the fading simulator.
Parameters:
<RestartMode>
AUTO | MANual
AUTO
: fading automatically starts with the DL signal
MANual
: fading is started and restarted manually (see
CONFigure:EVDO:SIGN<i>:FADing:FSIMulator:
RESTart
*RST:
AUTO
Example:
See
Firmware/Software:
V3.2.80
Options:
R&S CMW-KE100 and R&S CMW-KE800
Manual operation:
See
CONFigure:EVDO:SIGN<i>:FADing:FSIMulator:STANdard
<Standard>
Selects one of the propagation condition defined in the table 6.4.1-1 of 3GPP2
C.S0032.
Parameters:
<Standard>
P1 | P2 | P3 | P4 | P5
EVDO1 to EVDO5
P1
: Two paths, speed 15 km/h (band classes 5, 11), 8 km/h
(other band classes)
P2
: One path, speed 3 km/h, exception: 6 km/h for band classes
5, 11
P3
: One path, speed 30 km/h, exception: 58 km/h for band
classes 5, 11
P4
: Three paths, speed 100 km/h, exception: 192 km/h for band
classes 5, 11
P5
: Two paths, speed 0 km/h
*RST: