![Rohde & Schwarz CMW-KE100 User Manual Download Page 336](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807336.webp)
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
336
User Manual 1173.9511.02 ─ 12
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:PERR:RMS
<PErrRMS>
Defines a symmetric limit for the RMS values of the phase error. The limit check fails if
the absolute value of the measured phase error exceeds the specified value.
Parameters:
<PErrRMS>
Range:
0 deg to 180 deg
*RST:
13.6 deg
Default unit: deg
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.3.3
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:PERR:PEAK
<PErrPeak>
Defines a symmetric limit for the peak values of the phase error. The limit check fails if
the absolute value of the measured phase error exceeds the specified value.
Parameters:
<PErrPeak>
Range:
0 deg to 180 deg
*RST:
19.6 deg
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.3.3
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:IQOFfset
<IQOffset>
Defines an upper limit for the I/Q origin offset.
Parameters:
<IQOffset>
Range:
-120 dB to -20 dB
*RST:
-25 dB
Default unit: dB
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.3.3
Manual operation:
See
Command Reference