<5_MErrPeak>
Magnitude error peak value
Range:
-100 % to 100 % (AVERage: 0% to 100 %, SDEVi-
ation: 0 % to 50 %)
Default unit: %
<6_PErrRMS>
Phase error RMS value
Range:
0 deg to 180 deg
Default unit: deg
<7_PErrPeak>
Phase error peak value
Range:
-180 deg to 180 deg (AVERage: 0 deg to 180 deg,
SDEViation: 0 deg to 90 deg)
Default unit: deg
<8_IQOffset>
I/Q origin offset
Range:
-100 dB to 0 dB
Default unit: dB
<9_IQImbalance>
I/Q imbalance
Range:
-100 dB to 0 dB
Default unit: dB
<10_CFreqError>
Carrier frequency error
Range:
-5000 Hz to 5000 Hz
Default unit: Hz
<11_TransTimeErr> Transmit time error
Range:
-100 µs to 100 µs
Default unit: µs
<12_ATPow1M23>
Access terminal power, measured with a filter bandwidth of 1.23
MHz
Range:
-100 dBm to 50 dBm
Default unit: dBm
<13_ATPowWide>
Access terminal power, measured with the wideband filter
Range:
-100 dBm to 50 dBm
Default unit: dBm
<14_WavQuality>
Waveform quality
Range:
0 to 1
<15_WavQualMaxP> Waveform quality at maximum power
Range:
0 to 1
<16_WavQualMinP> Waveform quality at minimum power
Range:
0 to 1