![Rohde & Schwarz CMW-KE100 User Manual Download Page 202](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807202.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
202
User Manual 1173.9511.02 ─ 12
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:APRobes:PLSLots
<PLSlots>
Defines the length in slots of the access probe preamble.
Parameters:
<PLSlots>
S4 | S16
4/16 slot preamble
*RST:
S16
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:APRobes:SAMRate
<SAMRate>
Defines the maximum rate at which the AT may transmit on the access channel.
Parameters:
<SAMRate>
R9K | R19K | R38K
9.6/19.2/38.4 kbps data rate
*RST:
R9K
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
2.5.9.5
Security
CONFigure:EVDO:SIGN<i>:NETWork:SECurity:SKEY
...................................................... 202
CONFigure:EVDO:SIGN<i>:NETWork:SECurity:OPC
........................................................203
CONFigure:EVDO:SIGN<i>:NETWork:SECurity:AUTHenticat
.............................................203
CONFigure:EVDO:SIGN<i>:NETWork:SECurity:SQN
........................................................203
CONFigure:EVDO:SIGN<i>:NETWork:SECurity:SKEY
<SecretKey>
Sets/gets the shared authentication key of the EAP-AKA' access authentication.
Command Reference
深圳德标仪器