![Rohde & Schwarz CMW-KE100 User Manual Download Page 208](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807208.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
208
User Manual 1173.9511.02 ─ 12
Example:
See
Configuring Message Monitoring
Firmware/Software:
V3.0.10
Manual operation:
See
2.5.11 RX Measurement
The following commands control the RX Measurements ("PER", "Throughput", "Data")
and retrieve the results.
"1xEV-DO Signaling" parameters
All RX measurements are based on an application stream that is configured and initi-
ated by the "1xEV-DO Signaling" application. Hence, adequate configuration of the
"1xEV-DO Signaling" application is a prerequisite.
The commands described in this section are only the ones related to measurement
control, statistics, limits, and measurement results.
Enable and Disable Measurements
...................................................................... 208
............................................................................................209
.............................................................................................211
.................................................................................................213
Additional Softkeys and Hotkeys
...........................................................................217
............................................................................................ 217
............................................................................................ 221
2.5.11.1
Enable and Disable Measurements
The following commands selectively enable/disable the RX measurements.
CONFigure:EVDO:SIGN<i>:RXQuality:RESult:FLPer
<Enable>
CONFigure:EVDO:SIGN<i>:RXQuality:RESult:FLPFormance
<Enable>
CONFigure:EVDO:SIGN<i>:RXQuality:RESult:RLPer
<Enable>
CONFigure:EVDO:SIGN<i>:RXQuality:RESult:RLPFormance
<Enable>
CONFigure:EVDO:SIGN<i>:RXQuality:RESult:IPSTatistics
<Enable>
Enables/disables the view of the following RX measurements as indicated by the last
mnemonics: "Forward Link PER", "Forward Link Performance" (Throughput), "Reverse
Link PER", "Reverse Link Performance" (Throughput) and "RLP & IP Statistics" (Data).
For a disabled view results are neither displayed nor calculated.
Parameters:
<Enable>
OFF | ON
*RST:
ON
Example:
See
Firmware/Software:
V3.0.20