1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
221
User Manual 1173.9511.02 ─ 12
FETCh:EVDO:SIGN<i>:RXQuality:FLPer:CSTate?
FETCh:EVDO:SIGN<i>:RXQuality:FLPFormance:CSTate?
Returns status information about the carrier.
Return values:
<Reliability>
See
<CarrierStatus>
OK | VIOLated | STALe | INACtive
Example:
See
Perform Forward Link Measurements
Usage:
Query only
Firmware/Software:
V3.0.10
V3.2.20: command renamed
Options:
R&S CMW-KS890 required for throughput measurements
2.5.11.8
Reverse Link Results
The following commands return the results of the reverse link "PER" and "Throughput"
measurements.
FETCh:EVDO:SIGN<i>:RXQuality:RLPer?
....................................................................... 221
READ:EVDO:SIGN<i>:RXQuality:RLPer?
........................................................................ 221
CALCulate:EVDO:SIGN<i>:RXQuality:RLPer?
..................................................................221
CALCulate:EVDO:SIGN<i>:RXQuality:RLPFormance?
...................................................... 223
FETCh:EVDO:SIGN<i>:RXQuality:RLPFormance?
............................................................223
READ:EVDO:SIGN<i>:RXQuality:RLPFormance?
.............................................................223
FETCh:EVDO:SIGN<i>:RXQuality:RLPer:STATe?
............................................................ 225
FETCh:EVDO:SIGN<i>:RXQuality:RLPFormance:STATe?
.................................................225
FETCh:EVDO:SIGN<i>:RXQuality:RLPer:CSTate?
........................................................... 225
FETCh:EVDO:SIGN<i>:RXQuality:RLPFormance:CSTate?
................................................225
FETCh:EVDO:SIGN<i>:RXQuality:RLPer?
[<DataRate>]
READ:EVDO:SIGN<i>:RXQuality:RLPer?
[<DataRate>]
CALCulate:EVDO:SIGN<i>:RXQuality:RLPer?
[<DataRate>]
Returns the "Reverse Link PER" measurement results for
●
the specified data rate
●
the selected carrier (in multi-carrier scenarios, see
chapter 2.2.14.3, "Reverse Link
Packet Error Rate Measurement"
The related carrier has to be pre-selected using the
command.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Command Reference