![Rohde & Schwarz CMW-KE100 User Manual Download Page 767](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807767.webp)
CDMA2000 Measurements
R&S
®
CMW-KM8xx/-KS8xx
767
User Manual 1173.9511.02 ─ 12
Fig. 5-30: OLTR: measurement overview
Traces
The results can be retrieved via the following remote commands.
Remote command:
FETCh:CDMA:MEAS<i>:RPINterval:SEQuence<Sequence>:TRACe:UP?
etc.
FETCh:CDMA:MEAS<i>:RPINterval:SEQuence<Sequence>:TRACe:DOWN?
etc.
FETCh:CDMA:MEAS<i>:OLTR:SEQuence<Sequence>:TRACe:UP?
etc.
FETCh:CDMA:MEAS<i>:OLTR:SEQuence<Sequence>:TRACe:DOWN?
etc.
Limit violation
The results can be retrieved via remote commands below.
Remote command:
FETCh:CDMA:MEAS<i>:OLTR:SEQuence<Sequence>:TRACe:DOWN:STATe?
etc.
FETCh:CDMA:MEAS<i>:OLTR:SEQuence<Sequence>:TRACe:UP:STATe?
etc.
5.3.13 Additional Softkeys and Hotkeys
The CDMA2000 TX measurement provides some softkey/hotkey combinations which
have no equivalent in the configuration dialog. Most of these hotkeys provide display
configurations (like diagram scaling). They are self-explanatory and do not have any
remote-control commands assigned.
The remaining softkeys / hotkeys are described below. They are displayed only while
the combined signal path scenario is active and are provided by the "CDMA2000 Sig-
naling" application selected as master application. See also
GUI Reference