User Manual 1173.9511.02 ─ 12
// *************************************************************************
// Select the wideband filter for AT power measurements.
// *************************************************************************
CONFigure:EVDO:MEAS:MEValuation:CARRier:SETTing 0
CONFigure:EVDO:MEAS:MEValuation:CARRier:WBFilter F16M0
// *************************************************************************
// Define a multi-carrier configuration: enable carrier 1 with a frequency
// offset of 2 MHz and query the resulting carrier frequency.
// *************************************************************************
CONFigure:EVDO:MEAS:MEValuation:CARRier:SETTing 1
CONFigure:EVDO:MEAS:MEValuation:CARRier:ENABle ON
CONFigure:EVDO:MEAS:MEValuation:CARRier:FOFFset 2000000
CONFigure:EVDO:MEAS:MEValuation:CARRier:FREQuency?
// *************************************************************************
// Define that only the first half-slot shall be measured. Settings
// per carrier: Analyze signal only when DRC, DSC, data or auxiliary
// pilot channels are present, for subtype 0/1 do not analyze signal
// if ACK channel is present, set data modulation type to BPSK.
// *************************************************************************
CONFigure:EVDO:MEAS:MEValuation:HSLot FHSLot
CONFigure:EVDO:MEAS:MEValuation:CARRier:SELect 0
CONFigure:EVDO:MEAS:MEValuation:DRC ON
CONFigure:EVDO:MEAS:MEValuation:ACKDsc DSC
CONFigure:EVDO:MEAS:MEValuation:DATA ON
CONFigure:EVDO:MEAS:MEValuation:APILot ON
CONFigure:EVDO:MEAS:MEValuation:ACK OFF
CONFigure:EVDO:MEAS:MEValuation:DMODulation B4
CONFigure:EVDO:MEAS:MEValuation:CARRier:SELect 1
CONFigure:EVDO:MEAS:MEValuation:DRC ON
CONFigure:EVDO:MEAS:MEValuation:ACKDsc DSC
CONFigure:EVDO:MEAS:MEValuation:DATA ON
CONFigure:EVDO:MEAS:MEValuation:APILot ON
CONFigure:EVDO:MEAS:MEValuation:ACK OFF
CONFigure:EVDO:MEAS:MEValuation:DMODulation B4
// *************************************************************************
// Define stop condition (stop on limit failure) and error handling.
// Carrier 0 and 1: Define 4 symmetrical active frequency offsets for ACP
// and extended ACP with resolution bandwidth 100 kHz.
// *************************************************************************
CONFigure:EVDO:MEAS:MEValuation:SCONdition OLFail
CONFigure:EVDO:MEAS:MEValuation:MOEXception ON
CONFigure:EVDO:MEAS:MEValuation:CARRier:SELect 0
CONFigure:EVDO:MEAS:MEValuation:ACP:FOFFsets:LOWer -1,-1.1,-1.2,-1.3,OFF,OFF,
OFF,OFF,OFF,OFF
CONFigure:EVDO:MEAS:MEValuation:ACP:EXTended:FOFFsets:LOWer -1,-1.1,-1.2,
-1.3,OFF,OFF,OFF,OFF,OFF,OFF,OFF,OFF,OFF,OFF,OFF,OFF,OFF,OFF,OFF,OFF