![Rohde & Schwarz CMW-KE100 User Manual Download Page 142](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807142.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
142
User Manual 1173.9511.02 ─ 12
The related carrier has to be pre-selected using the
command.
Parameters:
<CarrierChannel>
The range of possible channels depends on the destination
cell's selected band class. For an overview see
on page 30. The values below are for band
class BC0 (US Cellular).
Range:
1 to 799, 991 to 1323
*RST:
183
Example:
See
Firmware/Software:
V2.1.20: Channel offset specification (relative to carrier 0) for
carriers 1 and 2
V3.0.10: Direct channel assignment for carriers 1 and 2
CONFigure:EVDO:SIGN<i>:HANDoff:CARRier:FLFRequency?
Gets the forward link frequency for a carrier in the handoff destination cell.
The related carrier has to be pre-selected using the
command.
This frequency is determined by the handoff destination cell's main carrier channel and
the related carrier's channel offset.
Return values:
<CFwdLinkFreq>
Range:
100E+6 Hz to 6.1E+9 Hz
Example:
See
Usage:
Query only
Firmware/Software:
V2.1.20
Options:
Multi-carrier support requires R&S CMW-KS881.
Manual operation:
See
CONFigure:EVDO:SIGN<i>:HANDoff:CARRier:RLFRequency?
Gets the reverse link frequency for a carrier in the handoff destination cell.
The related carrier has to be pre-selected using the
command.
This frequency is determined by the handoff destination cell's main carrier channel and
the related carrier's channel offset.
Return values:
<CRevLinkFreq>
Range:
100E+6 Hz to 6.1E+9 Hz
Example:
See
Usage:
Query only
Command Reference
135-1095-0799