1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
132
User Manual 1173.9511.02 ─ 12
<SyncState>
PENDing | ADJusted
PENDing:
the generator has been turned on (off) but the signal
is not yet (still) available
ADJusted:
the physical output signal corresponds to the main
generator state (signal off for main state OFF, signal on for main
state ON)
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
V3.0.10: RFHandover state added
Manual operation:
See
CALL:EVDO:SIGN<i>:CSWitched:ACTion
<CSAction>
Controls the setup and release of an 1xEV-DO connection. The command initiates a
transition between different connection states; to be queried via
Setting parameters:
<CSAction>
CONNect | DISConnect | CLOSe | HANDoff
Transition between connection states
Example:
See
Usage:
Event
Firmware/Software:
V1.0.15.0
Mode:
All connection states
Manual operation:
See
FETCh:EVDO:SIGN<i>:CSWitched:STATe?
Returns the connection state of an 1xEV-DO connection. Use
to initiate a transition between different connection states.
The connection state changes to
ON
as soon as the signaling generator is started
ON). To make sure that a forward 1xEV-DO signal
is actually available, query the sector state:
SOURce:EVDO:SIGN<i>:STATe:ALL?
must return
ON, ADJ
.
Return values:
<CSState>
OFF | ON | IDLE | SNEGotiation | SOPen | PAGing |
CONNected
Connection state; for details refer to
Example:
See
Command Reference