![Rohde & Schwarz CMW-KE100 User Manual Download Page 198](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807198.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
198
User Manual 1173.9511.02 ─ 12
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:CNTCode
<CNTCode>
Defines the 3-digit decimal representation of the country code associated with the sec-
tor.
Parameters:
<CNTCode>
Range:
0 to 999
*RST:
999
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:FORMat
<Format>
Selects the input format for the 128-bit overall sector ID.
Parameters:
<Format>
A41N | MANual
ANSI-41 or manual entry
*RST:
A41N
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:ID:ANSI
<ANSI41SectorID>
Defines the 24-bit sector ID, to be used if the ANSI-41 format is selected
(
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:FORMat
).
Parameters:
<ANSI41SectorID>
Sector ID, 6-digit hexadecimal number
Range:
#H000000 to #HFFFFFF
*RST:
255
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:NPBits
<ANSI41PBits>
Defines the number of parity bits, to be used if the ANSI-41 format is selected
(
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:FORMat
).
Parameters:
<ANSI41PBits>
Range:
1 to 64
*RST:
9
Command Reference