![Rohde & Schwarz CMW-KE100 User Manual Download Page 749](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807749.webp)
CDMA2000 Measurements
R&S
®
CMW-KM8xx/-KS8xx
749
User Manual 1173.9511.02 ─ 12
Hotkey
Description
"Diagram View / Table
View"
Toggle between graphical and tabular presentation of the ACP and "Code
Domain" results.
"Enlarged Value ..."
Select the quantity to be displayed as enlarged value in the Power and Modula-
tion Quality views.
"Spreading Factor ..."
Select the spreading factor for CDP or CDE.
"Trace Result Order"
Select the order of the displayed code channels for CDP or CDE:
●
Hadamard: The order is determined by the Hadamard matrix. The codes
correspond to the Walsh code numbers n.
●
Bit reverse: The order is defined by the OVSF code tree. The codes corre-
spond to the OVSF code numbers k.
Additional options are available in the "Measurement Control" section of the configura-
tion dialog.
5.2.9.2
Using Markers
Use the "Marker" parameters to activate markers and to modify their position. The fol-
lowing "Marker" hotkeys are available at the bottom of the GUI:
Hotkey
Description
"Ref.
Marker ..."
Enable or disable the reference marker and select the marker position. If several traces
can be displayed, a trace can also be selected.
"Marker 1 /
2 ..."
Enable or disable marker 1 or 2 and define the marker position (absolute or relative to the
reference marker).
Depending on the trace mode, a trace can also be selected.
"Select Trace
Mode"
Define whether marker 1 and 2 are set to the same trace as the reference marker (collec-
tive) or to selectable individual traces.
"I-Signal / Q-
Signal"
For the code domain bar graphs there are independent sets of markers for the I-Signal bar
graph and the Q-Signal bar graph. This parameter switches between these sets of mark-
ers. The settings above apply to the selected set only.
See also: "Markers" in the R&S
CMW user manual, chapter "System Overview"
5.3 GUI Reference
The following sections provide detailed reference information on the parameters of the
CDMA2000 multi evaluation and open loop time response (OLTR) measurements. The
GUI reference is structured as follows.
............................................................................................750
Signal Routing and Analyzer Settings
...................................................................751
Multi Evaluation: Measurement Control
................................................................ 757
Multi Evaluation: Limit Settings
............................................................................. 759
GUI Reference