SENSe:EVDO:SIGN:IQOut:PATH1?
CONFigure:EVDO:SIGN:IQIN:PATH1 -30, -20
2.4.1.4
Configuring Internal Fading
// *****************************************************************************
// Select a standard cell scenario with internal fading.
// *****************************************************************************
ROUTe:EVDO:SIGN:SCENario:SCFading:INTernal RF2C,RX1,RF2C,TX1
// *****************************************************************************
// Configure the fading simulator: enable it,
// select a fading profile with speed 0 km/h, start fading
// automatically, set start seed and set insertion loss to
// 16 dB.
// *****************************************************************************
CONFigure:EVDO:SIGN:FADing:FSIMulator:ENABle ON
CONFigure:EVDO:SIGN:FADing:FSIMulator:STANdard P5
CONFigure:EVDO:SIGN:FADing:FSIMulator:RESTart:MODE AUTO
CONFigure:EVDO:SIGN:FADing:FSIMulator:GLOBal:SEED 0
CONFigure:EVDO:SIGN:FADing:FSIMulator:ILOSs:MODE USER
CONFigure:EVDO:SIGN:FADing:FSIMulator:ILOSs:LOSS 16
// *****************************************************************************
// Configure AWGN insertion: enable AWGN and set a signal to noise
// ratio and low limit for the noise bandwith to system bandwidth ratio.
// Query power of AWGN within channel, noise level within the DL
// channel, power of noise totally, and total power of signal
// plus noise.
// *****************************************************************************
CONFigure:EVDO:SIGN:FADing:AWGN:ENABle ON
CONFigure:EVDO:SIGN:FADing:AWGN:SNRatio -50
CONFigure:EVDO:SIGN:FADing:AWGN:BWIDth:RATio 10
CONFigure:EVDO:SIGN:FADing:AWGN:BWIDth:NOISe?
CONFigure:EVDO:SIGN:FADing:POWer:NOISe?
CONFigure:EVDO:SIGN:FADing:POWer:NOISe:TOTal?
CONFigure:EVDO:SIGN:FADing:POWer:SUM?
2.4.1.5
Configuring the Test Application
Example configuration of a test session. Select "forward and reverse" as link mode for
the test application.
// *************************************************************************
// Select the test application in forward and reverse direction.
// Query the stream the test application is using.
// Select the preferred packet mode eHRPD.
// Establish a connection and query the active application and
// negotiated mode.
Programming