![Rohde & Schwarz CMW-KE100 User Manual Download Page 403](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807403.webp)
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
403
User Manual 1173.9511.02 ─ 12
<3_OBW>}
Occupied bandwidth
Range:
0 to 16 MHz (SDEViation 0 to 8 MHz)
Default unit: MHz
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V2.0.20
Options:
R&S CMW-KM012
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
3.5.4.24
List Mode Results: Single Results, All Segments
Each of the following commands returns
●
a single measurement result (RRI RMS power, EVM peak value,...) ,
●
iterated over all active segments.
To configure the list mode use the commands in section
For additional information concerning syntax elements and returned values refer to
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:SRELiability?
.............................................408
FETCh:EVDO:MEAS<i>:MEValuation:LIST:SRELiability?
.................................................. 408
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:AVERage?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:CURRent?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:MAXimum?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:SDEViation?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:AVERage?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:CURRent?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:MAXimum?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:SDEViation?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:AVERage?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:CURRent?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:MAXimum?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:SDEViation?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:AVERage?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:CURRent?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:MAXimum?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:SDEViation?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:FERRor:AVERage?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:FERRor:CURRent?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:FERRor:MAXimum?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:FERRor:SDEViation?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:FERRor:AVERage?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:FERRor:CURRent?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:FERRor:MAXimum?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:MODulation:FERRor:SDEViation?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:MODulation:IQIMbalance:AVERage?
Command Reference