![Rohde & Schwarz CMW-KE100 User Manual Download Page 182](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807182.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
182
User Manual 1173.9511.02 ─ 12
Manual operation:
See
CONFigure:EVDO:SIGN<i>:LAYer:APPLication:FMCTap:DRC:SIZE?
Queries the size of the FMCTAP test packets sent on a particular carrier.
The related carrier has to be pre-selected using the
command.
The packet size is determined by the selected packet type (
SIGN<i>:LAYer:APPLication:FMCTap:DRC:TYPE
).
Return values:
<DRCSize>
Range:
128 to 5120
*RST:
128
Example:
See
Usage:
Query only
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
CONFigure:EVDO:SIGN<i>:LAYer:APPLication:FMCTap:DRC:RATE?
Queries the data rate of the FMCTAP test packet stream sent on a particular carrier.
The related carrier has to be pre-selected using the
command.
The data rate is determined by the selected packet type (
SIGN<i>:LAYer:APPLication:FMCTap:DRC:TYPE
).
Return values:
<DRCRate>
Range:
4.8 kbit/s to 3072 kbit/s
*RST:
4.8 kbit/s
Example:
See
Usage:
Query only
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
CONFigure:EVDO:SIGN<i>:LAYer:APPLication:FMCTap:DRC:SLOTs?
Queries the slot count of a FMCTAP test packet sent on a particular carrier.
The related carrier has to be pre-selected using the
command.
Command Reference
135-1095-0799