![Rohde & Schwarz CMW-KE100 User Manual Download Page 120](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807120.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
120
User Manual 1173.9511.02 ─ 12
2.4.1.10
Query AT-related Information
// *****************************************************************************
// Query AT RX power
// *****************************************************************************
SENSe:EVDO:SIGN:TEST:RX:POWer:STATe?
// *************************************************************************
// Query AT information
// *************************************************************************
CONFigure:EVDO:SIGN:CSTatus:UATI?
CONFigure:EVDO:SIGN:CSTatus:ESN?
CONFigure:EVDO:SIGN:TEST:CSTatus:ESN?
CONFigure:EVDO:SIGN:CSTatus:MEID?
CONFigure:EVDO:SIGN:TEST:CSTatus:MEID?
CONFigure:EVDO:SIGN:CSTatus:PCCHannel:CYCLe?
CONFigure:EVDO:SIGN:CSTatus:PCCHannel:ENABle?
CONFigure:EVDO:SIGN:CSTatus:ILCMask?
CONFigure:EVDO:SIGN:CSTatus:QLCMask?
SENSe:EVDO:SIGN:ATADdress:IPV4?
2.4.1.11
Configuring Reverse Power Control Setup
To execute a power control bits pattern, a connection has to be established before, see
chapter 2.4.1.8, "Setting up a Connection"
// *****************************************************************************
// Configure reverse power control of the AT: select the power control bits
// according to the "Pattern", select the step size and configure the segment
// bits and segment lenth for the continuous pattern execution. Start
// the power control. After the measurement switch off the pattern execution.
// *****************************************************************************
CONFigure:EVDO:SIGN:RPControl:PCBits PATT
CONFigure:EVDO:SIGN:RPControl:SSIZe 0.5
CONFigure:EVDO:SIGN:RPControl:REPetition CONT
CONFigure:EVDO:SIGN:RPControl:SEGMent1:BITS DOWN
CONFigure:EVDO:SIGN:RPControl:SEGMent2:BITS UP
CONFigure:EVDO:SIGN:RPControl:SEGMent1:LENGth 120
CONFigure:EVDO:SIGN:RPControl:SEGMent2:LENGth 120
CONFigure:EVDO:SIGN:RPControl:SEGMent3:LENGth 0
CONFigure:EVDO:SIGN:RPControl:SEGMent4:LENGth 0
CONFigure:EVDO:SIGN:RPControl:RUN ON
CONFigure:EVDO:SIGN:RPControl:RUN OFF
2.4.1.12
Handoff
// *************************************************************************
// Configure handoff parameters
Programming