![Rohde & Schwarz CMW-KE100 User Manual Download Page 363](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807363.webp)
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
363
User Manual 1173.9511.02 ─ 12
READ:EVDO:MEAS<i>:MEValuation:TRACe:ACP:AVERage[:RELative]?
READ:EVDO:MEAS<i>:MEValuation:TRACe:ACP:MAXimum[:RELative]?
CALCulate:EVDO:MEAS<i>:MEValuation:TRACe:ACP:CURRent[:RELative]?
CALCulate:EVDO:MEAS<i>:MEValuation:TRACe:ACP:AVERage[:RELative]?
CALCulate:EVDO:MEAS<i>:MEValuation:TRACe:ACP:MAXimum?
Returns the adjacent channel power measured at a series of frequencies. The current,
average and maximum traces can be retrieved.
The frequencies are determined by the offset values defined via the commands
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:FOFFsets:LOWer
and
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:FOFFsets:UPPer
. All defined
offset values are considered (irrespective of their activation status).
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Return values:
<Reliability>
<PowOffsetM9> ...
<PowOffsetM0>
<PowCarrier>
<PowOffsetP0> ...
<PowOffsetP9>
The power offsets <PowOffsetPn> (<PowOffsetMn>) refer to the
average power at the carrier frequency plus (minus) the fre-
quency offset value number n.
Range:
-100 dB to 20 dB
Default unit: dB
Example:
See
Multi Evaluation: Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.3.3
V3.0.10: CALCulate commands added
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
CALCulate:EVDO:MEAS<i>:MEValuation:TRACe:ACP:EXTended:CURRent:
ABSolute?
CALCulate:EVDO:MEAS<i>:MEValuation:TRACe:ACP:EXTended:AVERage:
ABSolute?
CALCulate:EVDO:MEAS<i>:MEValuation:TRACe:ACP:EXTended:MAXimum:
ABSolute?
FETCh:EVDO:MEAS<i>:MEValuation:TRACe:ACP:EXTended:CURRent:
ABSolute?
FETCh:EVDO:MEAS<i>:MEValuation:TRACe:ACP:EXTended:AVERage:
ABSolute?
FETCh:EVDO:MEAS<i>:MEValuation:TRACe:ACP:EXTended:MAXimum:
ABSolute?
READ:EVDO:MEAS<i>:MEValuation:TRACe:ACP:EXTended:CURRent:ABSolute?