![Rohde & Schwarz CMW-KE100 User Manual Download Page 797](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807797.webp)
CDMA2000 Measurements
R&S
®
CMW-KM8xx/-KS8xx
797
User Manual 1173.9511.02 ─ 12
<SyncState>
PEND | ADJ | INV
PEND:
waiting for resource allocation, adjustment, hardware
switching ("pending")
ADJ:
all necessary adjustments finished, measurement running
("adjusted")
INV:
not applicable because <MainState>: OFF or RDY ("inva-
lid")
<ResourceState>
QUE | ACT | INV
QUE:
measurement without resources, no results available
("queued")
ACT:
resources allocated, acquisition of results in progress but
not complete ("active")
INV:
not applicable because <MainState>: OFF or RDY ("inva-
lid")
Example:
See
Multi Evaluation: Single-Shot and Continuous Measure-
Usage:
Query only
Firmware/Software:
V1.0.2.7
Manual operation:
See
5.5.4.2
Enabling Results and Views
The following commands select the evaluated results and the displayed views.
CONFigure:CDMA:MEAS<i>:MEValuation:RESult[:ALL]
.................................................... 797
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:EVMagnitude
........................................ 799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:MERRor
............................................... 799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:PERRor
................................................799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:CDP
.....................................................799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:CDE
.....................................................799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:ACP
..................................................... 799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:OBW
.................................................... 799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:CP
....................................................... 799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:CPO
.....................................................799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:CTO
.....................................................799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:IQ
........................................................ 799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:POWer
................................................. 799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult:MODQuality
.......................................... 799
CONFigure:CDMA:MEAS<i>:MEValuation:RESult[:ALL]
<EVM>,
<MagnitudeError>, <PhaseError>, <ACP>, <CDP>, <CDE>, <Power>,
<TXMeasurements>[, <ChPower>, <OBW>, <ChPhaseOffset>,
<ChTimeOffset>, <IQ>]
Enables or disables the evaluation of results and shows or hides the views in the multi
evaluation measurement.
Command Reference
135-1095-0799