CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
562
User Manual 1173.9511.02 ─ 12
If the MS was in "Registered" state, the send method could be Service Option 6, 14 or
Access Channel. Otherwise; in "Connected" state always the Traffic Channel is used.
Remote command:
CONFigure:CDMA:SIGN<i>:SMS:INComing:FILE:INFO?
Clear Message Info
Resets all parameters related to a received SMS message. The message text and
information about the message length are deleted.
Remote command:
CLEan:CDMA:SIGN<i>:SMS:INComing:INFO
4.3.10.3
Broadcast
Configure settings for sending broadcast messages via PCH.
Option R&S CMW-KS810 is required.
Fig. 4-62: Messaging broadcast settings
WEA Message
Specifies whether the message is used for the measurement of the Wireless Emer-
gency Alerts (WEA) solution, formerly known as the Commercial Mobile Alert System
(CMAS), with focus on battery life time. This feature allows you to monitor the power
consumption of the MS in idle mode with and without cell broadcast impact on the
mobile device.
Note that the current version supports only WEA messages. No general broadcast
messages are supported.
Option R&S CMW-KS170 is required for the WEA feature.
Remote command:
CONFigure:CDMA:SIGN<i>:SMS:BROadcast:WEA