![Rohde & Schwarz CMW-KE100 User Manual Download Page 267](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807267.webp)
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
267
User Manual 1173.9511.02 ─ 12
For additional information see
Combined Signaling and Measurement
Remote command:
ROUTe:EVDO:MEAS<i>?
ROUTe:EVDO:MEAS<i>:SCENario?
ROUTe:EVDO:MEAS<i>:SCENario:SALone
ROUTe:EVDO:MEAS<i>:SCENario:CSPath
Connector / Converter
Selects the input path for the measured RF signal, i.e. the input connector and the RX
module to be used.
Depending on your hardware configuration there may be dependencies between both
parameters. Select the RF connector first. The "Converter" parameter offers only val-
ues compatible with the selected RF connector.
In the Standalone (SA) scenario, these parameters are controlled by the measurement.
In the Combined Signal Path (CSP) scenario, they are controlled by the signaling appli-
cation.
For connector and converter settings in the combined signal path scenario, use one of
the
ROUTe:EVDO:SIGN<i>:SCENario:...
signaling commands.
Remote command:
ROUTe:EVDO:MEAS<i>:SCENario:SALone
(SA)
ROUTe:EVDO:SIGN<i>:SCENario:...
(CSP)
External Attenuation (Input)
Defines the value of an external attenuation (or gain, if the value is negative) in the
input path. The power readings of the R&S
CMW are corrected by the external attenu-
ation value.
The external attenuation value is also used in the calculation of the maximum input
power that the R&S
CMW can measure.
If a correction table for frequency-dependent attenuation is active for the chosen con-
nector, then the table name and a button are displayed. Press the button to display the
table entries.
In the Standalone (SA) scenario, this parameter is controlled by the measurement. In
the Combined Signal Path (CSP) scenario, it is controlled by the signaling application.
Remote command:
CONFigure:EVDO:MEAS<i>:RFSettings:EATTenuation
(SA)
SOURce:EVDO:SIGN<i>:RFSettings:RX:EATTenuation
(CSP)
CONFigure:EVDO:SIGN<i>:RFSettings:EATTenuation
(CSP)
Band / Channel / Frequency
Determines the center frequency of carrier 0. For single-carrier configurations this is
also used as the center frequency of the RF analyzer. For multi-carrier configurations
the RF analyzer is centered at the mean of the extremal carrier frequencies (see
Evaluation: Carrier Configuration
You can specify the RF frequency in two ways:
●
Enter the frequency directly. The band and channel settings can be ignored or
used for validation of the entered frequency. For validation select the designated
GUI Reference