CDMA2000 Measurements
R&S
®
CMW-KM8xx/-KS8xx
748
User Manual 1173.9511.02 ─ 12
●
Average:
Average of all "Current" values referenced to the last statistics cycle.
●
Min, Max:
Smallest or largest "Current" value that the R&S
CMW obtained since
the start of the measurement.
●
Max/Ext:
Largest or extreme "Current" value that the R&S
CMW obtained within
the measurement interval. For the error measurements (e.g. EVM, magnitude
error, phase error etc.) the extreme value is displayed (the biggest absolute value
with the correct sign).
Results for the waveform quality and EVM:
–
Remote command " ...:MAXimum?" for the objects with asymmetrical parame-
ters (e.g. waveform quality with the range 0 to 1 or EVM with the range 0% to
100%) queries the worst result.
–
Remote command "...:MINimum?" queries the best result, which is not relevant
therefore not displayed.
●
Std Dev:
Standard deviation of all "Current" values since the start of the measure-
ment.
All statistical results (statistical tables and "Average" or "Max" traces) are calculated
according to the general rules for statistical results.
See also: "Statistical Results" in the R&S
CMW user manual, chapter "System Over-
view"
Statistic Count
Progress bar for the measurement, displayed in all detailed views. During the first sin-
gle shot after the start of the measurement, the bar shows the number of elapsed mea-
surement intervals relative to the "Statistic Count". A filled progress bar indicates that
the first shot is complete and the statistical depth has been reached.
See also: "Statistical Settings" in the R&S
CMW user manual, chapter "System Over-
view"
Out of Tolerance
Percentage of measurement intervals that were failed because they exceeded the
specified limits.
5.2.9.1
Selecting and Modifying Views
Use the "Display" parameters to select the views and to change the appearance and
contents of the views. Depending on the selected view the following "Display" hotkeys
are available at the bottom of the GUI:
Hotkey
Description
"Select View ..."
Switch to a certain detailed view or overview.
Alternatively select a diagram in the overview and press ENTER or the rotary
knob.
"Select Trace ..."
Select the trace types to be displayed in the view.
"X Scale... / Y Scale..."
Modify the ranges of the X-axis and the Y-axis.