CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
566
User Manual 1173.9511.02 ─ 12
The "RX Meas Pilot Strength" requires a connection to the MS.
The "RX Meas Speech" requires a speech mode connection, e.g. service options 1, 3,
17, 68, 70, 73, 0x8000.
Remote command:
FER FCH
:
INITiate:CDMA:SIGN<i>:RXQuality:TDATa:FERFch
STOP:CDMA:SIGN<i>:RXQuality:TDATa:FERFch
ABORt:CDMA:SIGN<i>:RXQuality:TDATa:FERFch
FETCh:CDMA:SIGN<i>:RXQuality:TDATa:FERFch:STATe?
FETCh:CDMA:SIGN<i>:RXQuality:FERFch:TDATa:STATe:ALL?
FER SCH0
:
INITiate:CDMA:SIGN<i>:RXQuality:TDATa:FERSch
STOP:CDMA:SIGN<i>:RXQuality:TDATa:FERSch
ABORt:CDMA:SIGN<i>:RXQuality:TDATa:FERSch
FETCh:CDMA:SIGN<i>:RXQuality:TDATa:FERSch:STATe?
FETCh:CDMA:SIGN<i>:RXQuality:TDATa:FERSch:STATe:ALL?
RLP
:
The RLP measurement is being started and stopped in parallel with a packet data con-
nection (service option 33) or via "Reset Statistics" hotkey.
Pilot strength
:
INITiate:CDMA:SIGN<i>:RXQuality:PSTRength
STOP:CDMA:SIGN<i>:RXQuality:PSTRength
ABORt:CDMA:SIGN<i>:RXQuality:PSTRength
FETCh:CDMA:SIGN<i>:RXQuality:PSTRength:STATe?
FETCh:CDMA:SIGN<i>:RXQuality:PSTRength:STATe:ALL?
Speech
:
The speech measurement is being started and stopped in parallel with a speech mode
connection (service options 1, 3, 17, 68, 70, 73, 0x8000) or via "Reset Statistics" hot-
key.
Signaling Parameter (Softkey)
The "Signaling Parameter" softkey activates hotkeys that provide convenient access to
the most important signaling application settings from within the "CDMA2000 RX Mea-
surement" window.