CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
694
User Manual 1173.9511.02 ─ 12
Firmware/Software:
V1.0.15.0
V3.0.20: commands for "FERSCh" and "RLP" added
V3.2.10: command for "SPEech" added
V3.5.10: command for "PSTRength" added
Manual operation:
See
INITiate:CDMA:SIGN<i>:RXQuality:TDATa:FERFch
STOP:CDMA:SIGN<i>:RXQuality:TDATa:FERFch
ABORt:CDMA:SIGN<i>:RXQuality:TDATa:FERFch
INITiate:CDMA:SIGN<i>:RXQuality:TDATa:FERSch
STOP:CDMA:SIGN<i>:RXQuality:TDATa:FERSch
ABORt:CDMA:SIGN<i>:RXQuality:TDATa:FERSch
Starts, stops, or aborts the measurement:
●
INITiate...
starts or restarts the measurement; the R&S
CMW enters the
"RUN" state.
●
STOP...
causes a running measurement to stop after the current evaluation
period is terminated and valid results are available; the R&S
CMW enters the
"RDY" state.
●
ABORt...
causes a running measurement to stop immediately; the R&S
CMW
enters the "OFF" state.
Use
FETCh...STATe?
to query the current measurement state.
See also: "Measurement Control" in the R&S
CMW user manual, chapter "Remote
Control"
Example:
See
Usage:
Event
Firmware/Software:
V1.0.15.0 FCH
V3.0.10 Command for FCH renamed (token
TDATa
added)
V3.0.20 Command for FCH renamed (token
FERFch
added)
V3.0.20 SCH0
Manual operation:
See
INITiate:CDMA:SIGN<i>:RXQuality:PSTRength
STOP:CDMA:SIGN<i>:RXQuality:PSTRength
ABORt:CDMA:SIGN<i>:RXQuality:PSTRength
Starts, stops, or aborts the measurement:
●
INITiate...
starts or restarts the measurement; the R&S
CMW enters the
"RUN" state.
●
STOP...
causes a running measurement to stop after the current evaluation
period is terminated and valid results are available; the R&S
CMW enters the
"RDY" state.
●
ABORt...
causes a running measurement to stop immediately; the R&S
CMW
enters the "OFF" state.
Command Reference
135-1095-0799