![Rohde & Schwarz CMW-KE100 User Manual Download Page 374](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807374.webp)
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
374
User Manual 1173.9511.02 ─ 12
<RetriggerOption>
OFF | ON
Enables or disables the trigger system to start segment mea-
surement.
Note:
For the first segment (
<no>
= 1) the setting of this param-
eter is ignored. Since the general MELM measurement starts
with the measurement of the first segment. That mean always
with the first trigger event the first segment is measured.
OFF
: Disabled retrigger. The segment measurement is started
by the first trigger event.
ON
: Enables the retrigger. The list mode measurement contin-
ues only if a new event for this segment is triggered (retrigger).
*RST:
OFF
<PLSubtype>
ST01 | ST2 | ST3
Selects the physical layer protocol subtype.
ST01:
subtype 0 or 1
ST2:
subtype 2
ST3:
subtype 3
*RST:
ST2
<HalfSlot>
FHSLot | SHSLot | BHSLots
Specifies which half-slot(s) of the code channel is/are evaluated
for measurements using physical layer subtype 2 or 3 (see
parameter before).
Consider that the DSC channel and the ACK channel are trans-
mitted time-multiplexed on Walsh channel W
12
32
. The ACK is
transmitted on the first half-slot and the DSC on the second half-
slot.
FHSLot:
evaluate the first half-slot
SHSLot:
evaluate the second half-slot
BHSLots:
evaluate both half-slots
*RST:
BHSL
<LongCodeMaskI>
Specifies the long code mask for the I branch.
Range:
#H0 to #H3FFFFFFFFFF
*RST:
#H0
<LongCodeMaskQ> Specifies the long code mask for the Q branch.
Range:
#H0 to #H3FFFFFFFFFF
*RST:
#H0
<CMWSConnector> Optional parameter, as alternative to the command
CONFigure:EVDO:MEAS<i>:MEValuation:LIST:
SEGMent<no>:CMWS:CONNector
*RST:
R11
Example:
See
Firmware/Software:
V2.0.20
V2.1.20 Subtype 3 added in PLSubtype parameter
V3.2.70: added <CMWSConnector>