1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
147
User Manual 1173.9511.02 ─ 12
Example:
See
Firmware/Software:
V3.2.10
Options:
R&S CMW-KS888
Manual operation:
See
ROUTe:EVDO:SIGN<i>:SCENario:SCFading:INTernal
<RXConnector>,
<RXConverter>, <TXConnector>, <TXConverter>
Activates the "Standard Cell Fading: Internal" scenario and selects the signal paths.
The first I/Q board is selected automatically.
For possible connector and converter values, see
chapter 2.5.1.3, "Values for Signal
Parameters:
<RXConnector>
RF connector for the input path
<RXConverter>
RX module for the input path
<TXConnector>
RF connector for the output path
<TXConverter>
TX module for the output path
Example:
See
Firmware/Software:
V3.2.80
Options:
R&S CMW-KE100 and R&S CMW-KE800
Manual operation:
See
ROUTe:EVDO:SIGN<i>:SCENario:SCFading[:EXTernal]
<RXConnector>,
<RXConverter>, <TXConnector>, <TXConverter>, <IQConnector>
Activates the "Standard Cell Fading: External" scenario and selects the signal paths.
For possible connector and converter values, see
chapter 2.5.1.3, "Values for Signal
Parameters:
<RXConnector>
RF connector for the input path
<RXConverter>
RX module for the input path
<TXConnector>
RF connector for the output path
<TXConverter>
TX module for the output path
<IQConnector>
DIG IQ OUT connector for external fading of the output path
Example:
See
Firmware/Software:
V3.2.80
Manual operation:
See
Command Reference