![Rohde & Schwarz CMW-KE100 User Manual Download Page 189](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807189.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
189
User Manual 1173.9511.02 ─ 12
Parameters:
<MPSequences>
Range:
1 to 15
*RST:
3
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:LAYer:MAC:IPBackoff
<IPBackoff>
Defines the upper limit of the backoff range (in units of "Access Cycle Duration"
defined in the "Network" section) which the AT uses between access probes.
Parameters:
<IPBackoff>
Range:
1 to 15
*RST:
4
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:LAYer:MAC:IPSBackoff
<IPSBackoff>
Defines the upper limit of the backoff range (in units of "Access Cycle Duration"
defined in the "Network" section) which the AT uses between access probe sequen-
ces.
Parameters:
<IPSBackoff>
Range:
1 to 15
*RST:
8
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
"Inter-Probe Sequence Backoff"
CONFigure:EVDO:SIGN<i>:LAYer:MAC:DFTProtocol:DRC:COVer
<DRCCover>
Specifies the DRC Cover value that the AT is to use on its Data Rate Control (DRC)
Channel (for subtype 0/1 signals only).
Parameters:
<DRCCover>
Range:
1 to 6
*RST:
2
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
Command Reference