![Rohde & Schwarz CMW-KE100 User Manual Download Page 48](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807048.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
48
User Manual 1173.9511.02 ─ 12
MEID
Mobile Equipment Identifier, a 56-bit number (14-digit hexadecimal) which allows for a
larger number of ATs to be identified than in the existing ESN numbering system.
Remote command:
CONFigure:EVDO:SIGN<i>:CSTatus:MEID?
CONFigure:EVDO:SIGN<i>:TEST:CSTatus:MEID
Preferred Ctrl Ch Cycle
The control channel cycle in which the AT makes a transition out of the dormant state
in order to monitor the Control Channel.
Remote command:
CONFigure:EVDO:SIGN<i>:CSTatus:PCCHannel:CYCLe?
Preferred Ctrl Ch Enable
Indicates whether or not the AT selects the Preferred Control Channel Cycle. A value
of "0" means that AN and AT both use a common hash function to determine which
Preferred Control Channel Cycle to use. A value of "1" means that the AT tells the AN
which Preferred Control Channel Cycle is used.
Remote command:
CONFigure:EVDO:SIGN<i>:CSTatus:PCCHannel:ENABle?
Long Code Mask I and Q
The reverse traffic channel in phase and quadrature phase long code masks associ-
ated with the access terminal's session.
Remote command:
CONFigure:EVDO:SIGN<i>:CSTatus:ILCMask?
CONFigure:EVDO:SIGN<i>:CSTatus:QLCMask?
AT IPv4 Address, IPv6 Prefix
Display the IPv4 address and/or the IPv6 prefix that have been assigned to the AT by
the R&S
CMW. The AT indicates whether it supports IPv4 only or IPv6 only or both.
Depending on this information the R&S
CMW assigns either an IPv4 address or an
IPv6 prefix or both and displays the assigned values.
Remote command:
SENSe:EVDO:SIGN<i>:ATADdress:IPV<n>?
2.3.1.3
Access Network Control
The main view provides only the most important settings for fast access.
This pane allows you to modify the used channel, power, system ID, 1xEV-DO network
release.
GUI Reference
135-1095-0799