1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
138
User Manual 1173.9511.02 ─ 12
CONFigure:EVDO:SIGN<i>:TEST:CSTatus:MEID
<MEID>
Sets the mobile equipment identifier of the connected AT.
Parameters:
<MEID>
Range:
0 to 72.057594015
*RST:
0
Example:
See
Firmware/Software:
V3.2.70
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CSTatus:PCCHannel:CYCLe?
Queries the control channel cycle in which the AT makes a transition out of the dor-
mant state in order to monitor the Control Channel.
Return values:
<Cycle>
Range:
0 to 32767
Default unit: (control channel cycles)
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CSTatus:PCCHannel:ENABle?
Queries the state of the "Preferred Control Channel Enable" flag. The flag indicates
whether or not the AT selects the Preferred Control Channel Cycle.
Return values:
<Enable>
OFF | ON
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CSTatus:ILCMask?
Queries the reverse traffic channel in phase long code mask associated with the
access terminal's session.
Return values:
<LCMaskI>
The Long Code Mask in hexadecimal notation.
Range:
#H0 to #H3FFFFFFFFFF
Command Reference