1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
137
User Manual 1173.9511.02 ─ 12
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CSTatus:ESN?
Queries the Electronic Serial Number of the connected AT.
Return values:
<ESN>
8-digit hexadecimal number
Range:
#H0 to #HFFFFFFFF (8 digits)
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CSTatus:MEID?
Queries the Mobile Equipment Identifier of the connected AT.
Return values:
<MEID>
14-digit hexadecimal number
Range:
#H0 to #HFFFFFFFFFFFFFF (14 digits)
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:TEST:CSTatus:ESN
<ESN>
Sets the hard-coded Electronic Serial Number of the connected AT.
Parameters:
<ESN>
Range:
0 to 4.2949
*RST:
0
Example:
See
Firmware/Software:
V3.2.70
Manual operation:
See
Command Reference