![Rohde & Schwarz CMW-KE100 User Manual Download Page 278](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807278.webp)
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
278
User Manual 1173.9511.02 ─ 12
The frequency offsets and enabling of the measurement at these offsets can be
defined per carrier. For more details see 3GPP2 C.S0033-D, section 4.5., "Limitations
on Emission".
Remote command:
CONFigure:EVDO:MEAS<i>:MEValuation:CARRier:SELect
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:FOFFsets:LOWer
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:EXTended:FOFFsets:LOWer
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:FOFFsets:UPPer
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:EXTended:FOFFsets:UPPer
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:RBW:LOWer
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:EXTended:RBW:LOWer
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:RBW:UPPer
CONFigure:EVDO:MEAS<i>:MEValuation:ACP:EXTended:RBW:UPPer
3.3.9 Multi Evaluation: Limit Settings
The "Limits" in the multi evaluation configuration dialog define lower and/or upper limits
for the modulation, code domain and spectrum results. For details see
Fig. 3-26: Multi evaluation configuration: limits
GUI Reference
深圳德标仪器