![Rohde & Schwarz CMW-KE100 User Manual Download Page 632](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807632.webp)
CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
632
User Manual 1173.9511.02 ─ 12
Manual operation:
See
"Band Class, Channel, Frequency "
CONFigure:CDMA:SIGN<i>:RFSettings:RLFRequency?
Queries the reverse frequency.
Return values:
<Frequency>
Range:
0 Hz to 6.1E+9 Hz
*RST:
833.49E+6 Hz
Default unit: Hz
Example:
See
Specifying General Signaling Settings
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
"Band Class, Channel, Frequency "
CONFigure:CDMA:SIGN<i>:RFSettings:FOFFset
<FreqOffset>
Selects a positive or negative offset frequency to be added to the center frequency of
the forward and reverse link.
Parameters:
<FreqOffset>
Range:
-50E+3 Hz to 50E+3 Hz
*RST:
0 Hz
Default unit: Hz
Example:
See
Specifying General Signaling Settings
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:CDMA:SIGN<i>:RFPower:CDMA
<CDMAPower>
Sets the total CDMA output power. The value range depends on the RF output used
and the external attenuation set. The "CDMA Power" level does not include the AWGN
power level.
The allowed value range can be calculated as follows:
Range (CDMAPower) = Range (Output Power) - External Attenuation - AWGNPower
Range (Output Power) = -130 dBm to -5 dBm (RFx Com) or -120 dBm to 3 dBm (RFx
Out)
; please also notice the ranges quoted in the data sheet.
Parameters:
<CDMAPower>
Range:
-130 dBm to 0 dBm
*RST:
-70 dBm
Default unit: dBm
Example:
See
Specifying General Signaling Settings
Firmware/Software:
V1.0.15.0