![Rohde & Schwarz CMW-KE100 User Manual Download Page 57](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807057.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
57
User Manual 1173.9511.02 ─ 12
Fig. 2-19: Fading simulator settings
Enable
Enables/disables the fading simulator.
Remote command:
CONFigure:EVDO:SIGN<i>:FADing:AWGN:ENABle
Profile
Selects one of the propagation condition defined in the table 6.4.1-1 of 3GPP2
C.S0032.
Different fading propagation profiles support various vehicle speeds, numbers of paths,
path power and delay.
Remote command:
CONFigure:EVDO:SIGN<i>:FADing:FSIMulator:STANdard
Restart Event
In "Auto" mode, fading automatically starts with the forward signal. In "Manual" mode, it
is started and restarted manually.
Remote command:
CONFigure:EVDO:SIGN<i>:FADing:FSIMulator:RESTart
CONFigure:EVDO:SIGN<i>:FADing:FSIMulator:RESTart:MODE
Start Seed
Sets the start seed for the pseudo-random fading algorithm. This enables reproducible
fading conditions.
Remote command:
CONFigure:EVDO:SIGN<i>:FADing:FSIMulator:GLOBal:SEED