1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
201
User Manual 1173.9511.02 ─ 12
Parameters:
<PIncrement>
Range:
0 dB to 7.5 dB
Increment: 0.5 dB
*RST:
4 dB
Default unit: dB
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:APRobes:PPSequence
<PPSequence>
Defines the maximum number of access probes which ATs are to transmit in a single
access probe sequence.
Parameters:
<PPSequence>
Range:
1 to 15
*RST:
5
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:APRobes:PLENgth
<PLength>
Defines the length in frames of the access probe preamble.
Parameters:
<PLength>
Range:
1 frame to 6 frames
*RST:
1 frame
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:APRobes:ACDuration
<ACDuration>
Defines the length in slots of the access cycle.
Parameters:
<ACDuration>
S16 | S32 | S64 | S128
16/32/64/128 slot cycle
*RST:
S64
Command Reference