![Rohde & Schwarz CMW-KE100 User Manual Download Page 323](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807323.webp)
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
323
User Manual 1173.9511.02 ─ 12
CONFigure:EVDO:MEAS<i>:MEValuation:DATA
<CodeChSData>
Specifies a measurement condition for the selected carrier (see
MEAS<i>:MEValuation:CARRier:SELect
) based on the presence of the data
channel.
Parameters:
<CodeChSData>
DNCare | ON | OFF
DNCare:
evaluate the signal irrespective of the presence of the
channel
ON:
evaluate the signal only when the channel is present
OFF:
evaluate the signal only when the channel is not present
*RST:
DNC
Example:
See
Multi Evaluation: Specifying Measurement-Specific Settings
Firmware/Software:
V1.0.3.3
Manual operation:
See
"Carrier [n] > DRC, ACK/DSC, Data, Aux Pilot"
CONFigure:EVDO:MEAS<i>:MEValuation:APILot
<APilot>
Specifies a measurement condition for the selected carrier (see
MEAS<i>:MEValuation:CARRier:SELect
) based on the presence of the auxiliary
pilot channel.
The condition is only relevant for physical layer protocol subtypes 2 and 3 (see
CONFigure:EVDO:MEAS<i>:MEValuation:PLSubtype
).
Parameters:
<APilot>
DNCare | ON | OFF
DNCare:
evaluate the signal irrespective of the presence of the
channel
ON:
evaluate the signal only when the channel is present
OFF:
evaluate the signal only when the channel is not present
*RST:
DNC
Example:
See
Multi Evaluation: Specifying Measurement-Specific Settings
Firmware/Software:
V1.0.3.3
Manual operation:
See
"Carrier [n] > DRC, ACK/DSC, Data, Aux Pilot"
CONFigure:EVDO:MEAS<i>:MEValuation:DMODulation
<DModulation>
Specifies the data channel modulation type of the selected carrier (see
EVDO:MEAS<i>:MEValuation:CARRier:SELect
).
This setting is only relevant for measurements using physical layer subtype 2 or 3 (see
CONFigure:EVDO:MEAS<i>:MEValuation:PLSubtype
).
Command Reference
深圳德标仪器