// RETAP configuration (network revision A):
// set the minimum/maximum packet size index,
// get the resulting minimum/maximum packet size.
// *************************************************************************
CONFigure:EVDO:SIGN:LAYer:APPLication:RETap:SMIN:INDex 1
CONFigure:EVDO:SIGN:LAYer:APPLication:RETap:SMAX:INDex 12
CONFigure:EVDO:SIGN:LAYer:APPLication:RETap:SMIN:SIZE?
CONFigure:EVDO:SIGN:LAYer:APPLication:RETap:SMAX:SIZE?
// *************************************************************************
// FMCTAP configuration (network revision B): pre-select
// the carrier to be configured, set the packet type.
// Get the resulting DRC index, packet size, data rate and slot
// count. Verify loopback mode is enabled and "ACK Channel
// Modulation Type Fixed mode" is OFF, don't use "ACK channel
// bit fixed mode".
// Pick the next carrier and configure it appropriately ...
// *************************************************************************
CONFigure:EVDO:SIGN:CARRier:SETTing 0
CONFigure:EVDO:SIGN:LAYer:APPLication:FMCTap:DRC:TYPE 15
CONFigure:EVDO:SIGN:LAYer:APPLication:FMCTap:DRC:INDex?
CONFigure:EVDO:SIGN:LAYer:APPLication:FMCTap:DRC:SIZE?
CONFigure:EVDO:SIGN:LAYer:APPLication:FMCTap:DRC:RATE?
CONFigure:EVDO:SIGN:LAYer:APPLication:FMCTap:DRC:SLOTs?
CONFigure:EVDO:SIGN:LAYer:APPLication:FMCTap:LBACk:ENABle?
CONFigure:EVDO:SIGN:LAYer:APPLication:FMCTap:ACK:MTYPe?
CONFigure:EVDO:SIGN:LAYer:APPLication:FMCTap:ACK:FMODe NUSed
CONFigure:EVDO:SIGN:CARRier:SETTing 1
// CONFigure:...
// *************************************************************************
// RMCTAP configuration (network revision B): pre-select
// the carrier to be configured, set the minimum/maximum packet
// size index and get the resulting minimum/maximum packet sizes.
// Pick the next carrier and configure it appropriately ...
// *************************************************************************
CONFigure:EVDO:SIGN:CARRier:SETTing 0
CONFigure:EVDO:SIGN:LAYer:APPLication:RMCTap:SMIN:INDex 1
CONFigure:EVDO:SIGN:LAYer:APPLication:RMCTap:SMAX:INDex 12
CONFigure:EVDO:SIGN:LAYer:APPLication:RMCTap:SMIN:SIZE?
CONFigure:EVDO:SIGN:LAYer:APPLication:RMCTap:SMAX:SIZE?
CONFigure:EVDO:SIGN:CARRier:SETTing 1