1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
165
User Manual 1173.9511.02 ─ 12
The related pilot has to be pre-selected using the
command.
Note that a pilot can only be acquired by the AT if it is
●
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AN:
●
assigned to the AT (using
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AT:
Use
CONFigure:EVDO:SIGN<i>:CSTatus:AFLCarriers?
to obtain more informa-
tion on the carrier states.
Return values:
<AcquiredByAT>
OFF | ON
Example:
See
Query Carrier Acquisition Status
Usage:
Query only
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
2.5.6.6
Forward Traffic Channel
The following commands define the preamble MAC indices that the R&S
CMW trans-
mits on the forward traffic channels.
CONFigure:EVDO:SIGN<i>:MAC:INDex
<Rev0>, <RevA>[, <RevB>]
Sets/gets a pilot's (associated carrier's) MAC index.
The related pilot has to be pre-selected using the
command.
Parameters:
<Rev0>
Range:
5 to 63
*RST:
8+i for Pilot i=1,2,3
<RevA>
Range:
5 to 127
*RST:
8+i for Pilot i=1,2,3
<RevB>
Range:
5 to 127
*RST:
8+i for Pilot i=1,2,3
Example:
See
Firmware/Software:
V1.0.15.0
V2.1.20: Dependency on pre-selected pilot; optional parameter
RevB added
Options:
Rev. B support (including multiple pilots) requires option R&S
CMW-KS881.
Manual operation:
See
"MAC Index [Rev. 0] / [Rev. A] / [Rev. B]"