![Rohde & Schwarz CMW-KE100 User Manual Download Page 564](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807564.webp)
CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
564
User Manual 1173.9511.02 ─ 12
Fig. 4-63: Shortcut configuration
Select Menu
Preselects the default measurement for the corresponding "Go to..." softkey.
Select as fixed Target
If the box is checked, the caption of the corresponding "Go to..." button changes
according to the preselected measurement and this button will immediately open the
measurement. Otherwise, an intermediate dialog box is opened.
4.3.12 Message Monitoring
Messages exchanged between the signaling application and the DUT can be moni-
tored. For this purpose the messages are sent to an external PC.
See also: "Logging" in the R&S
CMW user manual, chapter "Basic Instrument Func-
tions"
Fig. 4-64: Message Monitoring
Add CDMA2000 Signaling to logging
If enabled, messages exchanged between the CDMA2000 signaling application and
the DUT are reported to the selected logging PC.
Remote command:
CONFigure:CDMA:SIGN<i>:MMONitor:ENABle
Logging PC IPv4 Address
Selects the IP address to which the messages shall be sent for monitoring.
The address pool is configured globally, see "Setup" dialog, section "Logging".
Remote command:
CONFigure:CDMA:SIGN<i>:MMONitor:IPADdress