![Rohde & Schwarz CMW-KE100 User Manual Download Page 193](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807193.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
193
User Manual 1173.9511.02 ─ 12
CONFigure:EVDO:SIGN<i>:LAYer:MAC:DRTProtocol:DONom?
Defines the nominal offset of the Reverse Traffic Channel power from the Reverse
Pilot Channel power.
At present, this parameter is not supported.
Return values:
<DataOffsetNom>
Range:
depending on test settings
*RST:
0 dB
Default unit: dB
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:LAYer:MAC:DRTProtocol:DRATe
<R9K>, <R19K>,
<R38K>, <R76K>, <R153K>
Defines the ratio of the Reverse Traffic Channel power at different data rates to the
Reverse Pilot Channel power.
Parameters:
<R9K>
Range:
-2 dB to 1.75 dB
Increment: 0.25 dB
*RST:
0 dB
Default unit: dB
<R19K>
Range:
-2 dB to 1.75 dB
*RST:
0 dB
Default unit: dB
<R38K>
Range:
-2 dB to 1.75 dB
Increment: 0.25 dB
*RST:
0 dB
Default unit: dB
<R76K>
Range:
-2 dB to 1.75 dB
Increment: 0.25 dB
*RST:
0 dB
Default unit: dB
<R153K>
Range:
-2 dB to 1.75 dB
Increment: 0.25 dB
*RST:
0 dB
Default unit: dB
Example:
See
Firmware/Software:
V1.0.15.0
Command Reference
深圳德标仪器