1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
111
User Manual 1173.9511.02 ─ 12
// Specify Open Loop Rule expected nominal power of the DUT and
// query the expected nominal power that the DUT has to transmit.
//
// Alternativelly set the expected power manually.
// *****************************************************************************
CONFigure:EVDO:SIGN:RFPower:EPMode OLRule
CONFigure:EVDO:SIGN:RFPower:EXPected?
CONFigure:EVDO:SIGN:RFPower:EPMode MAN
CONFigure:EVDO:SIGN:RFPower:MANual -30
// *****************************************************************************
// Specify AWGN mode and level.
// *****************************************************************************
CONFigure:EVDO:SIGN:RFPower:MODE:AWGN NORM
CONFigure:EVDO:SIGN:RFPower:LEVel:AWGN -10
// *************************************************************************
// Set the channels for carriers 1 and 2 and
// query their forward and reverse link frequencies.
// *************************************************************************
CONFigure:EVDO:SIGN:CARRier:SETTing 1
CONFigure:EVDO:SIGN:CARRier:CHANnel 160
CONFigure:EVDO:SIGN:CARRier:FLFRequency?
CONFigure:EVDO:SIGN:CARRier:RLFRequency?
CONFigure:EVDO:SIGN:CARRier:SETTing 2
CONFigure:EVDO:SIGN:CARRier:CHANnel 170
CONFigure:EVDO:SIGN:CARRier:CHANnel?
CONFigure:EVDO:SIGN:CARRier:FLFRequency?
CONFigure:EVDO:SIGN:CARRier:RLFRequency?
// *************************************************************************
// Set the main carrier's power and query total power (including AWGN).
// *************************************************************************
CONFigure:EVDO:SIGN:RFPower:EVDO -50
CONFigure:EVDO:SIGN:RFPower:OUTPut?
// *************************************************************************
// Set the relative power levels for carriers 1 and 2 and
// query their absolute power levels
// *************************************************************************
CONFigure:EVDO:SIGN:CARRier:SETTing 1
CONFigure:EVDO:SIGN:CARRier:LEVel:RELative -5
CONFigure:EVDO:SIGN:CARRier:LEVel:ABSolute?
CONFigure:EVDO:SIGN:CARRier:SETTing 2
CONFigure:EVDO:SIGN:CARRier:LEVel:RELative -10
CONFigure:EVDO:SIGN:CARRier:LEVel:ABSolute?
// *************************************************************************
// Specify MAC index for all carriers.